Most likely fix:
A. If it’s the first time you start the heater, to exhaust the extra air completely, please try start it couple of times.
B. Disconnect the gas hose from the gas inlet and check if the gas is flowing. If the regulator is defective the gas will not flow and the unit will not ignite.
C. Check if you have enough propane.
D. If you are using a new tank of gas, the solenoid valve may not work because the gas pressure is too high. Try to turn on the water faucet first, gas source valve later. And try to start the heater again.
E. Disconnect the shower hose and shower head and let the water gush out from the heater (set gas knob to minimum and water knob to maximum), if that fix the problem there is clog either in shower hose or shower head.
PRECAUTION:
F. Please make sure the water heater is connected to the correct type of gas line. If the unit is LP it should be connected to LP line or NG to NG line. It’s possible to cause an ignition failure or an explosion when connected to the wrong gas line. It’ll produce yellow flame or black smoke if connected to the wrong gas line.
*If this did not help, please schedule a call with our technical support team for further troubleshooting help. We are always happy to help!